NEW POLAR2- Coming Soon!
Details:
Reichert Polar2 Advantages
Optimized for pharmaceutical applications
Best accuracy - remains constant throughout measurement range
Exceptional high-quality analysis
Modular concept to grow with requirements
Different T-Cell polarimeter tubes for normal or small volumes
Self-calibration automatic wavelength control (AWC)
Multiple wavelength option
Continuous reading
Low maintenance
Compliant to international standards, GLP/GMP conformity and 21 CFR Part 11 ready
Energy saving and no maintenance LED light source
Reichert Polarimeter Operating System Software
The operating system (OS) software has been designed with the user in mind. The intuitive touchscreen navigation saves time when defining settings or changing methods. The OS can easily connect the Reichert Polar2 and the Polar 3, to the AR series of refractometers, the AR9 and the AR5, and density meters, Density5 and Density4, making your lab ready for all applications. This powerful software makes the instrument part of your workflow communicating with LIMS systems and other laboratory instruments via USB or RS232. The software operates up to 7 customer-specific methods in the Polar1 and up to 1,000 in the Polar2 and Polar3. Combine the OS with the optional, GxP software package to provide full compliance with 21 CFR Part 11 meeting all security electronic records requirements for the pharmaceutical industry.
Advantages of Reichert Operating System Software
Context sensitive lab to easily customize your workflow and maximize efficiency
Intuitive interface guides user through the menu
Quick set-up of specific measurement scales
Storage for more than 1,000 products including up to 1,000 methods
Password protected administration and user profiles
Evaluate and calculate displayed values and data
Easy to calibrate with self-diagnostic options
Traceability of all calibration procedures
Export interface to MS Excel, text file or PDF
Quick reset to factory defaults
Quick reset to user specific defaults
Easy service and support references
USB interface allows upgrades at user site
Universal Display
Operation system displayed on 7” color touchscreen
Drives up to 5 measurement modules
Program and save testing methods
GxP Software Package
Provides compliance for 21 CFR part 11 meeting all security requirements for critically regulated industries
Technical Specifications:
Measurement Scales Optical Rotation, Specific Rotation, OZ International Sugar Scale, % Concentration
User Definable Scales 1,000
Measuring Range ± 90° / ± 259°Z
Resolution 0.001° / 0.01°Z
Accuracy ± 0.01° / ± 0.03°Z
Reproducibility ± 0.01° / ± 0.03°Z
Sensitivity Up to OD 2
Wavelengths 589nm standard, others on request
Response Time 6 to 8 sec. over entire measuring range
Tube Lengths Up to 100 mm length
Tube Materials Glass, acid-proof stainless steel, stainless steel with temperature sensor
Temperature Interface
Temperature
measurement NTC Sensor
Accuracy ± 0.01°C
Temperature range 10°C to 40°C
Resolution 0.01°C
Additional Information
Light source - LED
Display - 4.3" color touchscreen/Universal Display optional
Interfaces - RS232, USB, Ethernet
Dimensions - 17 x 12 x 6.3 inches (430 x 300 x 160 mm)
Weight - 22 lbs. (9.97 kg)
Details:
Reichert Polar2 Advantages
Optimized for pharmaceutical applications
Best accuracy - remains constant throughout measurement range
Exceptional high-quality analysis
Modular concept to grow with requirements
Different T-Cell polarimeter tubes for normal or small volumes
Self-calibration automatic wavelength control (AWC)
Multiple wavelength option
Continuous reading
Low maintenance
Compliant to international standards, GLP/GMP conformity and 21 CFR Part 11 ready
Energy saving and no maintenance LED light source
Reichert Polarimeter Operating System Software
The operating system (OS) software has been designed with the user in mind. The intuitive touchscreen navigation saves time when defining settings or changing methods. The OS can easily connect the Reichert Polar2 and the Polar 3, to the AR series of refractometers, the AR9 and the AR5, and density meters, Density5 and Density4, making your lab ready for all applications. This powerful software makes the instrument part of your workflow communicating with LIMS systems and other laboratory instruments via USB or RS232. The software operates up to 7 customer-specific methods in the Polar1 and up to 1,000 in the Polar2 and Polar3. Combine the OS with the optional, GxP software package to provide full compliance with 21 CFR Part 11 meeting all security electronic records requirements for the pharmaceutical industry.
Advantages of Reichert Operating System Software
Context sensitive lab to easily customize your workflow and maximize efficiency
Intuitive interface guides user through the menu
Quick set-up of specific measurement scales
Storage for more than 1,000 products including up to 1,000 methods
Password protected administration and user profiles
Evaluate and calculate displayed values and data
Easy to calibrate with self-diagnostic options
Traceability of all calibration procedures
Export interface to MS Excel, text file or PDF
Quick reset to factory defaults
Quick reset to user specific defaults
Easy service and support references
USB interface allows upgrades at user site
Universal Display
Operation system displayed on 7” color touchscreen
Drives up to 5 measurement modules
Program and save testing methods
GxP Software Package
Provides compliance for 21 CFR part 11 meeting all security requirements for critically regulated industries
Technical Specifications:
Measurement Scales Optical Rotation, Specific Rotation, OZ International Sugar Scale, % Concentration
User Definable Scales 1,000
Measuring Range ± 90° / ± 259°Z
Resolution 0.001° / 0.01°Z
Accuracy ± 0.01° / ± 0.03°Z
Reproducibility ± 0.01° / ± 0.03°Z
Sensitivity Up to OD 2
Wavelengths 589nm standard, others on request
Response Time 6 to 8 sec. over entire measuring range
Tube Lengths Up to 100 mm length
Tube Materials Glass, acid-proof stainless steel, stainless steel with temperature sensor
Temperature Interface
Temperature
measurement NTC Sensor
Accuracy ± 0.01°C
Temperature range 10°C to 40°C
Resolution 0.01°C
Additional Information
Light source - LED
Display - 4.3" color touchscreen/Universal Display optional
Interfaces - RS232, USB, Ethernet
Dimensions - 17 x 12 x 6.3 inches (430 x 300 x 160 mm)
Weight - 22 lbs. (9.97 kg)